The OSN902 is a WDM transmission platform customized for Data Center Interconnect (DCI) applications. Its large transmission capacity, adaptation to installation conditions in DC equipment rooms, and simple management mode provide an optimal user experience on DCI carrier networks.
Based on open TSDN software architecture, the OSN902 provides various open interfaces. DCI users can perform secondary development to integrate this product’s management into DC device management systems, reduce the difficulties in routine maintenance, and ensure the development of rapidly increasing DC services.
- High Integration2U-high chassis provides a transmission capacity of 2.4 Tbit/s, and low power consumption (less than 0.5W/G), which can save space and power.
- Large CapacityAdopts beyond 100G optical transmission technology, achieving 200G single-wavelength, and flexible grid enables 20+ Tbit/s single-fiber, meeting data center bandwidth requirements and saving fiber resources.
- Hot-SwappableFans, power, service boards, and optical modules are hot-swappable and can be replaced within 15 seconds.
Specifications
Specifications | Details |
Dimensions (H x W x D) | 86.1 mm x 442 mm x 600 mm, 19 inch cabinet |
Number of Service Slots | 6 slots, 2.4T/Subrack |
Line Side | Single Wavelength 100G (PDM-QPSK)/200G (PDM-16QAM) programmable |
Client Side | Pluggable QSFP+/QSFP28, supporting 10 GE/40 GE/100 GE service access |
Channel Spacing | 100 GHz fixed grid for 40/48 wavelengths 50 GHz fixed grid for 80/96 wavelengths 37.5 GHz to 400 GHz flex grid |
Rate per Channel (maximum) | 100G/200G |
Management | CLI/SNMP/NETCONF/U2000/Corba |
Operational Features | L1 Encryption (AES256) LLDP |
Power Supply | 1+1 power supply redundancy AC power: 90V to 264V AC High voltage DC power: 192V to 288V HVDC |
Heat Dissipation | 2+1 fan module redundancy, ventilation from front to rear |
For inquiries, email us at info@agdinfotech.com
Source: https://e.huawei.com/en/products/enterprise-transmission-access/transmission/wdm/osn-902